23 Error Type-Code Description Replacement Parts * Part most likely to resolve issue ** Part less likely to resolve issue 3-2 System lid open while rinsing  Check if magnet is secure in system lid * System lid lock assembly ** System switch assembly ** User interface board ** Main controller board 3-3 Power module fault detected * Main controller board 3-4 User interface to main controller communication error * User interface board * Main control board 3-10 Invalid float level sensor assembly state * Float level sensor assembly ** Main controller board 4-1 Invalid float level sensor assembly state * Float level sensor assembly ** Main controller board 4-2 Timeout waiting for low water level 1.

Check for water available at inlet 2. Check water pressure at inlet * Cleaning tank assembly ** Inlet hose ** Main controller board ** Float level sensor assembly 4-3 Timeout waiting for mid water level 1. Check for water available at inlet 2. Check water pressure at inlet * Cleaning tank assembly ** Float level sensor assembly ** Main controller board 4-4 Unexpected transition to overfill condition * Float level sensor assembly ** Cleaning tank assembly ** Main controller board 4-5 Timeout waiting for full water level 1. Check for water available at inlet 2.

Check water pressure at inlet * Float level sensor assembly * Cleaning tank assembly ** Main controller board 4-6 Float level sensor assembly error - empty switch stuck closed * Float level sensor assembly ** Main controller board 4-7 Timeout waiting for full water level 1. Check for water available at inlet 2. Check water pressure at inlet * Float level sensor assembly * Cleaning tank assembly ** Main controller board 4-8 Overfill:

Float level sensor assembly error - mid switch stuck open * Float level sensor assembly ** Main controller board 4-9 Float level sensor assembly error - mid switch stuck open * Float level sensor assembly ** Main controller board 4-10 Float level sensor assembly error - empty switch stuck closed * Float level sensor assembly ** Main controller board 4-11 Not empty at start of fill * Float level sensor assembly ** Main controller board 4-12 Float level sensor assembly error (full before mid) * Float level sensor assembly ** Main controller board 4-13 Not at target level at the end of fill * Float level sensor assembly ** Main controller board 5-1 Invalid float level sensor assembly state * Float level sensor assembly ** Main controller board