Diagnostic and Test Specifications Functional Description Overview The diagnostic test feature is intended to allow the support engineer to con- firm correct operation of a majority of the system’s hardware. Diagnostic test- ing does not require water be connected to the cleaning tank assembly for the test sequence to complete successfully. The support engineer will be required to verify certain hardware is operating properly where the cleaning tank assembly itself is not capable of detecting it automatically. Entering Diagnostic Mode Diagnostic mode can only be entered when the system is initially powered off.
To enter diagnostic mode, the support engineer must simultaneously hold down only the ‘start’ and ‘load select’ buttons (farthest apart) when power is turned on. The system is now in diagnostic mode (indicated by both 'cycle load' LEDs being ON simultaneously and all ‘cycle length’ and ‘progress sta- tus’ LEDs OFF, neither of which should ever occur during normal operating mode). Normal operation cannot be resumed until this mode is exited. Note that the input buttons have different functions when in diagnostic mode. Press Together Input functions in Diagnostic Mode The affect of pressing the interface panel buttons changes when diagnostic mode is active.
25 Button Normal mode (for reference only) Diagnostic model Cycle ‘Load Select’ Rotate though water level options (FullHalfFull...) Select subtest (sequential Cycle ‘Length Select’ Rotate though cycle length options (Long Med Short Long...) Run selected subtest ‘Start’ Begin selected cleaning operation Run all diagnostic subtests (run remaining subtests) ‘Cancel’ Abort any operation in progress Exit diagnostic mode(abort current subtest)