Float Level Sensor Assembly Required Tools • #2 phillips screwdriver • Anti-seize compound Hardware • #8 lock washer (x2) • 8-32 x 3/8” phillips screw (x7) Removing the float level sensor assembly 1. Remove the back panel. See “Removing the back panel” on page 39 . 2. Remove the user interface board. See “Removing the user inter- face board” on page 49 . 3. Remove the cleaning tank assembly. See “Removing the clean- ing tank assembly” on page 60 . 4. Remove the agitation assembly. See “Removing the agitation assembly” on page 65 . 5. Using a #2 phillips screwdriver, remove 5 cable routing clamps. See Figure 52 . 6. Lift the float level sensor assembly out of the agitation assembly. 7.
Using a #2 phillips screwdriver, remove the 2 screws that attach the float level sensor assembly to the agitation assembly. 8. Remove the float level sensor assembly from the agitation assembly. 72