HP — Umbilical cable pinouts

Signal Information Signal ground Toggle in model position. In position = 0 V Toggle Sensors Toggle in support position. In position = 0 V X Axis Sensors X EOT sensor. Sensor is NC = 5VDC. Open = 1.8VDC. See TP18 and DL3 on PDB X BOT sensor. Sensor is NC = 5VDC. Open = 1.8VDC. See TP19 and DL4 on PDB Up position = 5 V. Signal in normally high (in up position).

Substrate Detect Square wave that drives the opto sensor Head Motor Encoder Encoder signal (phase 1 from head drive motor encoder) Encoder signal (phase 2 from head drive motor encoder) Head Motor Power Power to head drive motor - 12 VDC Power to head drive motor - 12 VDC Over Temp Alarm Chamber/Head area is over temp (+100C) Chip located on T/C Amp Board T/C Signals Normal = 0 V. Over temp alarm = +4 V Support T/C signal (0.010 = 1 C). Signal amplified on T/C Amp Board Model T/C signal (0.010 = 1 C).

Signal amplified on T/C Amp Board Signal ground Signal ground Signal ground -130 Pin Signal P505-6 GND P505-21 MODEL TOGGLE IN _ _ P505-10 SUPPORT TOGGLE IN _ _ P505-11 XEOT IN _ P505-22 XHOME IN _ P506-7 SUBSTRATE DETECT IN _ _ P506-2 SUBSTRATE CLK OUT _ _ P506-8 HD MTR PH0 1 _ _ _ P506-3 HD MTR PH1 1 _ _ _ P506-9 HD MOTOR OUT 1 _ _ _ P506-4 HD MOTOR OUT 2 _ _ _ P506-10 CHAMBER TEMP ALARM _ _ P506-6 SUPPORT TC _ P506-11 MODEL TC _ P506-12 GND P506-1 GND P506-5 GND