Part curling Characteristics: Top surface appears rough. Model and support will separate or support and substrate will separate. Corrective actions: 1. The part is too dense, try using the “Sparse Fill” option in HP Designjet Software Solution. 2. Modeling base has been re-used or is defective. Replace with unused modeling base. 3. Run Z Calibrations. 4. Verify proper operation of all chamber fans. Replace fans as needed. 5. Verify chamber heaters are secured and operating properly. Replace heaters as needed. 6. Verify X, Y and Z level is within specification. If not level, re-level and calibrate. -142