Power Distribution Board (PDB) Figure 5: PDB Detail This board provides the power required to run the system. AC line voltage, +5 VDC, +12 VDC, and +24 VDC feed into the PDB. An additional +120 VDC input feeds into the PDB for the support head heater.
-14 A J1 AC Power In B J2 Power Switch/Thermostat C J3 Chamber Heaters D J22 Auxillary 120VDC power supply E J8 Z BOT, Z EOT, Chamber Fans, Frame ID, Filament detect sensor (not used) F J9 Z motor G J10 I/O board connection H J11 I/O board connection I J7 24VDC input J Test points and LEDs (see detail in this section) K J4 5/12VDC input L Voltage indicator LEDs (see detail in this section) M J12 To material bay N J16 To external UPS (optional) O J18 LCD display from SBC P J15 To controller board (ribbon cable) Q J14 To controller board (ribbon cable) R J13 To controller board (ribbon cable)