Test Points and LED’s Test points and LED’s are very useful for troubleshooting the system. The test points and LED’s are listed below with a brief description. Figure 6: Test points and LEDs detail -16 Component Test Pt.
Description UPS TP29 Power fail signal from external UPS +5V REF TP24 Head T/C service reference Door Switch TP15 State of the door (open or closed) On/Off Switch TP14 State of power down switch Power Enable TP8 Enables power to circuitry (normally high) Model Toggle TP17 Toggle travel complete Chamber Thermocouple TP28 Voltage corresponds to chamber temperature (10 mV=° C) Support Thermocouple TP20 Voltage corresponds to support temperature (10 mV=° C) Model Thermocouple TP22 Voltage corresponds to model temperature (10 mV=° C) HD Thermostat TP25 Chamber and head thermostat (snap switches) (+5 VDC if both switches closed) Normal = tp17 lo, tp19 hi ch thermostat fault=tp17 lo, tp19 lo.
Head TC Alarm TP26 High if head T/C not plugged in or open Support Toggle TP16 Not used Chamber TC Alarm TP27 High if chamber T/C not plugged in or open