HP — Checking/Adjusting the Y-Drive Belt Tension

Checking/Adjusting the Y-Drive Belt Tension NOTE: The Y-Drive system consists of two drive belts - one on each side of the build envelope. Each belt must be checked, adjusted and of equal values. 1. Remove the top, side and side access panels. 2. If required, allow system to cool to room temperature (approximately 20 minutes). 3. Move the Head Assembly to full rear travel within the build envelope 4. Position the dial indicator on the top section of the Y-Drive belt at the center point of the belt. ( Figure 398 ) Figure 398: Y-Drive Belt Tension Check Y-Drive Belt clamp (one on each side). Dial Indicator position for Y-Drive belt tension check. 5.

The large hand on the gauge should read between 0 and 30 mils and the small hand should read between 4 and 5 ( Figure 399 ). -384