HP — Tip calibration:

Tip calibration: Tip replacement requires Tip Calibration. 1. Select Start Part (flashing) - the printer will run two calibration parts. • The printer will automatically build a Z Calibration part, measure the part and calibrate the Z Axis for tip depth and tip level (approx- imately 5 minutes). The Z calibration is automatic. • The printer will then automatically build an XY Calibration part (approximately 10 minutes). You must inspect the XY Calibration part and calibrate the X and Y axis for tip offset: 2. When the XY Calibration part is complete the printer will display Remove Part and Select XY Adjustment - X:0, Y:0 3. Remove the XY tip calibration part from the printer. 4.

Inspect the part and calibrate the X and Y axis. See Figure 54. A. Use the magnifier from the Startup kit to view the support road (shown in red). B. Identify the location on the +X or –X side of the part where the support road is best centered within the model boundaries (shown in blue). C. Read the number closest to this location. This is the required X Tip Offset adjustment. If the number is on the -X side, a negative offset is required. D. Select Increment or Decrement to input the X offset adjustment - the value will change in the upper display window (by default, the printer will be ready to accept the X value). E.

When you are satisfied with your X offset value, Select Y and repeat steps A- D to identify and input the required Y Tip Offset adjustment. -71