omron — Stopping Time and Distance

Chapter 8: Technical Specifications Stopping Time and Distance X Stopping Distance (Hornet565 J4) 400 Stopping Distance (mm) 300 Payload 33% Vmax 5.9m/s Payload 66% Vmax 5.8m/s 200 100 Payload 100% Vmax 5.7m/s 0 0 20 40 60 80 100 120 Speed (%) Figure 8-7. Hornet 565 X Stopping Distance with J4 Platform X Stopping Time (Hornet565 J4) 0.15 Payload 33% Vmax 5.9m/s Stopping Time (s) 0.10 Payload 66% Vmax 5.8m/s 0.05 Payload 100% Vmax 5.7m/s 0.00 0 20 40 60 80 100 120 Speed (%) Figure 8-8. Hornet 565 X Stopping Time with J4 Platform Hornet 565 Robot User's Guide, 14608-000 Rev C Page 137 of 156