omron — Installation Procedure

Chapter 6: Options Figure 6-6. Bottom of Cable Entry Top Cover, CF Frame 3. Adapt Roxtec modules to fit the cables that will be used by peeling out half-circle strips from the modules. There should be a 0.1 to 1.0 mm gap between the halves of the mod- ules for a proper seal. See the following figure. Figure 6-7. Adapting a Module to the Cable Size, Checking the Gap 4. Grease the Roxtec modules, using Roxtec grease. See the following figure. Figure 6-8. Greasing a Roxtec Module 5. Grease the inside of the CF frame, where the modules will touch, using Roxtec grease. 6. Install each eAIB cable through its corresponding module, and insert the modules into the frame. See the following figure.

Ensure that the terminated cable ends have 10 - 12 in. of slack. See Figure 6-11. Hornet 565 Robot User's Guide, 14608-000 Rev C Page 92 of 156