HP — Using the SCANtest 6 Diagnostic Software

● Scanner ID Switch: ● SCSI ID: Test 2: LED Test This test checks the functionality of the LED Indicators on the Operator Panel. When the test is executed, all the LEDs are sequentially switched ON/OFF until Test 2 is terminated. If any of the LEDs fail, you will NOT get an error message, instead the LED will NOT switch ON or OFF. If the LED test fails, replace the Right Cover (which contains the Operator Panel). Test 3: Key Test This test checks the functionality of the Keys on the Operator Panel. When the test is executed, each key on the Operator Panel will turn the LED ON when pressed. The only way to know if the test fails is by inspection, there is no error message that is displayed.

If the Key test fails, replace the Right Cover (which contains the Operator Panel). Test 4: Original-Sensor Test This test checks the functionality of the Media Sensors. When the test is executed, the following LEDs turn ON when one of the Media Sensors is activated. To test the Media Sensors, load a Sheet of media (A4) and the Ready LED switches ON and when you remove it the Ready LED switches OFF. If the test fails (if any of the LEDs fail to switch ON), then the problem will be related to corresponding Sensor. Test 5: Lamp Test This test checks the functionality of the Lamp and associated electronics.

When the test is executed, a message on the screen will indicate whether the Lamp is turned ON or OFF ( Lamp power is turned ON/OFF ) and whether the Light is ON/OFF ( Light is detected or not ). The Lamp is delayed for approximately 2 seconds when switched ON. Test 6: Motor Test This test checks the functionality of the Stepper Motor and any associated electronics. When the test is executed, a menu appears that allows you to select the motor speed and the motor direction. 4 Chapter 1 Troubleshooting ENWW Key LED Forward and Reverse Ready (Green) Power Wait (Yellow) ATAC control key Actuator LED Media Entry Sensor Ready (Green) Media Exit Sensor Ready (Green)