hewlett-packard HP 9835A — 167

I/O Handling 167 Because of the possibility that a RESET ( IC@ll@ffi), or similar interruption, may occur between the first and second calls to the utility, it is recommended that the first call have a definite valid value for the select code in A (as above). In that way, should there indeed be an interruption, a valid select code for the printer can be assured. Utility: Print_string General Procedure: The utility is given the address of a string, and it prints that string to the standard system printer. Special Requirements: The string to be printed must be in standard string format (see "Data Structures" in Chapter 3). The string must be no longer than 506 characters. Calling Procedure: 1.

Load register A with the address of the string to be printed. 2. Call the utility. Exit Conditions: RET 1 If a memory overflow occurs during execution of the utility. RET 2 If the @ffi key is pressed during execution of the utility. RET 3 If all goes normally. For example - ":'T' '! _.. 1 ~ i i- :"'·F":· "!: l!' '1:::'::::.:- ~-."" CAUTION Pressing RESET (lcoNnll STOP I) during execution of the Print string utility may cause a SCRATCH A to occur. - I