6. Full parameter list EN-14 Parameter No. Description Factory Setting n001 Parameter Access 1 n002 Control Mode Selection 0 (Note1, 4) n003 RUN Command 0 n004 Frequency Reference Selection 1 n005 Stopping Method Selection 0 n006 Reverse Run Prohibit 0 n007 Stop Key Selection 0 n008 Frequency Reference Selection in Local Mode 1 n009 Frequency Reference Setting Method From Digital Operator 0 n010 Detecting Fault Contact of Digi- tal Operator 0 n011 Max. Output Frequency 50.0Hz n012 Max. Voltage 200V (Note 2) n013 Max. Voltage Output Frequency 50.0Hz n014 Mid. Output Frequency 1.3Hz (Note 4) n015 Mid. Output Frequency Voltage 12.0V (Note 2,4) n016 Min. Output Frequency 1.3Hz (Note 4) n017 Min.
Output Frequency Voltage 12.0V (Note 2,4) n018 Selecting Setting Unit for Acceleration/deceleration Time 0 n019 Acceleration Time 1 10.0s n020 Deceleration Time 1 10.0s n021 Acceleration Time 2 10.0s Parameter No.
Description Factory Setting n022 Deceleration Time 2 10.0s n023 S-curve Selection 0 n024 Frequency Reference 1 (Master Frequency Reference) 6.00Hz n025 Frequency Reference 2 0.00Hz n026 Frequency Reference 3 0.00Hz n027 Frequency Reference 4 0.00Hz n028 Frequency Reference 5 0.00Hz n029 Frequency Reference 6 0.00Hz n030 Frequency Reference 7 0.00Hz n031 Frequency Reference 8 0.00Hz n032 Jog Frequency 6.00Hz n033 Frequency Reference Upper Limit 100% n034 Frequency Reference Lower Limit 0% n035 Setting/displaying Unit Selec- tion for Frequency Reference 0 n036 Motor Rated Current (Note 3) n037 Electronic Thermal Motor Protection Selection 0 n038 Electronic Thermal Motor Pro- tection Time Constant Setting 8min n039 Selecting Cooling Fan Operation 0 n040 Motor Rotation Direction 0 n041 Acceleration Time 3 10.0s n042 Deceleration Time 3 10.0s n043 Acceleration Time 4 10.0s