ibm PCjr — 2-100

Note: Errors will be signaled by the processor with a short tone from the audio alarm or external speaker. Operational Parameters The operational distance from infra-red devices to the system should not exceed 6.1 meters (20 feet) (line-of-sight). Operational efficiency can be impaired by outside sources. These sources are, excessively-bright lights, and high-voltage lines, which include some TV sets. High-energy sources will generally cause an audible alarm within the system unit. These sources may downgrade the operational distance from the keyboard to the system. A keyboard cable is recommended if the above interference conditions are not controllable.

Pin Signal Input/Output AOI +12 Volts Input A02 Ground Input A03 Ground-Shield Input A04 I.R. TEST FREQ. Input BOI GROUND Input B02 +5 Volts Input B03 -I.R. KBD DATA Output B04 GROUND Input Infra-Red Connector Specifications 2-100 Infra-Red Link