signal-jumper manufactured into particular program-cartridges that are intended to replace the system ROM. Note: When the cartridge is inserted or removed with the system turned on, the system will I reset I and go through a warm power-up. Any data in the system RAM will be lost. Cartridge Storage Allocations A. The following conventions will be followed for "Initial Program Loadable" program cartridges: Location Contents 0 055H 1 OAAH 2 Length 3,4,5 Jump to Initialize Code 6 0 Last 2 Addresses CRC Bytes Storage Conventions • Locations 0 and 1 contain the word hex 55AA.
This is used as a test for the presence of the cartridge during the configuration- determination portion of the power-on routines. • Location 2 contains a length indicator representing the entire address space taken by the ROM on the cartridge. The algorithm for determining the 2-108 Program Cartridge