ibm PCjr — 2-126

operations are going to be overlapped with keyboard receive operations, the Async Receiver rate cannot exceed 1200 baud. This is due to the processor deserialization of the keyboard. See mM PC jr Cordless Keyboard in this section for more information. Programming Note: Due to the read/write cycle-time of the 8250A, it is recommended that back-to-back I/O operations to the 8250A be avoided. A good Programming Technique would be to insert a short I jump I between every consecutive 8250 I/O instruction. This action will flush the queue and provide 15 clock periods between I/O operations. Note: This note only applies to programmers using the 8250A directly.

It is STRONGLY suggested that the user not communicate directly with the physical hardware, but use the system BIOS instead. Note: It is important to note that when the mM PCjr has the Internal Modem installed it is logically COMI and the RS232 serial port is logically COM2 in BIOS, DOS, and BASIC. Without the Internal Modem installed the RS232 serial port is logically addressed as COMl in BIOS, DOS ,and BASIC even though its address is still hex 2F8 using Interrupt level 3. The following figure is a Serial Port Block Diagram: 2-126 Serial Port