Signal Bit Name Description MSB7 -BUSY When this signal is at a low level, the printer is busy and cannot accept data. It can become low during data entry, off-line printing, head translation, or error state. 6 -ACK When port B is read, this bit will represent the current state of the printer ACK signal. A low level means that a character has been received and the printer is ready to accept another. Normally, this signal will be low for approximately 5 microseconds before BUSY goes away. 5 -PE A low level indicates that the printer has detected an end of form. 4 +SLCT A high level indicates that the printer is selected.
3 -ERROR A low level indicates that the printer has encounted an error condition. 2 Unused. Through OLSB Printer Status Printer Control - Address hex 37 A This port contains printer control signals. A I write I latches control bits to the printer; a I read I presents the contents of the latches to the processor. See the following timing diagram: Parallel Printer Attachment 3-101