2. If the new translated scan code is less than hex 56, it is processed by BIOS as a keyboard scan-code and the same data is placed in the BIOS keyboard buffer. 3. If the translated scan-code is greater than hex 55 or the incoming scan-code is outside the range of the translate table, hex 40 is added, creating a new extended-sean-code. The new extended-sean-code is then placed in the BIOS keyboard buffer with the character code of OO(null). This utilizes the range hex 96 th..--u BE for scan codes hex 56 thru 7E respectively. The default translate-table maps scan codes hex 56 thru 6A to existing keyboard-values.
Scan codes hex 6B thru BE are mapped (by adding hex 40) to extended codes of hex AB thru FE, since these are out side the range of the default translate-table. Users can modify Interrupt Hex 49 to address their own translate table if mapping differences are desired. The translate table format is: Description o Length - The number of non-keyboard scan-codes that are mapped within the table (from 1 to n). 1 to n Word with low-order byte representing the scan-code-mapped values relative to the input values in the range of hex 56 thru 7E. Keyboard Encoding 5-43