omron — Standard Driver Sheets

Communication with Other Devices Tip: By default, the project will scan the communication worksheet every 600 milliseconds, which is the rate at which the system tag BlinkSlow toggles. To adjust the rate, manually edit the project file (i.e., projectname .APP ) to add the following entry: [Options] MainDrvAlwaysTrigger= tagname tagname can be either another system tag (e.g., BlinkFast , Second , Minute ) or a tag that you have created. Whenever the value of the tag changes, the worksheet will be scanned and the tags will be read. Standard Driver Sheets In addition to the unique MAIN DRIVER SHEET that is available for each driver, you can create several STANDARD DRIVER SHEETS for each driver.

The STANDARD DRIVER SHEETS provide additional fields, which you can use to control communication. To open a STANDARD DRIVER SHEET, right-click on a driver subfolder and select Insert from the resulting popup (see the following figure). Sample STANDARD DRIVER SHEET The STANDARD DRIVER SHEET dialog is divided into two areas: • Header area (top section), contains parameters that affect the all tags configured in the Body area of this worksheet • Body area (bottom section), where you define the relationship between tags in the project and their field equipment address. Use the Header area parameters as follows: • Description field:

Type a description of the STANDARD DRIVER SHEET for documentation purposes. • Increase Priority checkbox: Click (check) to keep the reading and writing commands for this sheet on the top of the communication queue whenever they are triggered. Caution: You must give special attention to this worksheet when you enable the Increase Priority option. If the worksheet keeps triggering communication commands, the project may never be able to execute the other driver sheets. • Read Trigger field: Type a tag that triggers the project to read the worksheet automatically when you change this tag's value. • Enable Read when Idle field: Type a tag or constant value.

Use a tag (or constant) value greater than zero, to enable reading from the equipment. Caution: If you use a constant value (other than zero), be sure that your project requires a continuous reading because this value places a reading request in every communication scan. • Read Completed field: Type in a tag and the communication driver toggles the tag when it completes a read command. • Read Status field: Type in a tag and the communication driver updates the tag with the status of the last read command. Page 298 InduSoft Web Studio