Communication with Other Devices 5. Click OK to close the Advanced dialog and return to the worksheet. 6. In the Status box, type the name of a tag (Integer type) that will receive connection status codes during project runtime. 7. In the Status Message box, type the name of a tag (String type) that will receive the corresponding status messages. 8. In the Publish Rate box, type the frequency (in milliseconds) at which the client will request updates from the server. 9. In the Disable box, type a tag/expression. When the value is TRUE (non-zero), the worksheet will not be executed.
10.In the Root node or view box, specify the server node that will serve as the root for all items in the worksheet body. Specifying a root node makes it easier to find items and improves runtime performance. 11.For each row of the worksheet body, specify the following: • Tag Name : The name of a project tag. You may use indirect tags (e.g., {MyTag} ), but if you do, then be sure to configure the Reload trigger option above. • Item : The server item with which the project tag should be associated. To browse the server's list of items, right-click in this field and then click Browse on the shortcut menu. • Scan : If Always , then the row is continuously scanned during runtime.
If Screen , then the row is scanned only when a project screen that uses the specified tag is open. • Div : For scaling — the value is divided by this number when reading from the server, and it is multiplied by this number when writing to the server. • Add : For scaling — this number is added to the value when reading from the server, and it is subtracted from the value when writing to the server. 12.Save and close the worksheet. • Instance ID : The instance ID is automatically generated from the full path of the server item.
InduSoft Web Studio Page 311 Area / Element Description Status The name of a tag (Integer type) that will receive a status code for the last read operation performed by a trigger. Status message The name of a tag (String type) that will receive the corresponding status message. Maximum aging N/A for OPC .Net Client. Write actions Enable write on tag change When this value is TRUE (non-zero), a write will be automatically performed whenever the value of the project tag changes. Note: This is enabled by default. If it is disabled, then you must use a write trigger (see below). Maximum group size The maximum number of tag writes to be performed in a single write operation.
For example, if you have 1000 items/rows configured in the worksheet and Maximum group size is set to 100, then 10 write operations will be performed during each scan of the worksheet. Synchronous write trigger When the value of this tag/expression changes, the worksheet is scanned and all tag values are written to the server. The project waits for the scan to complete before continuing. Asynchronous write trigger N/A for OPC .Net Client. Write count The name of a tag (Integer type) that will receive a count of the number of write operations performed since the project was run.
Status The name of a tag (Integer type) that will receive a status code for the last write operation performed by a trigger. Status message The name of a tag (String type) that will receive the corresponding status message. Reload trigger Indirect tags (e.g., {MyTag}) configured in the body of the worksheet will be reloaded only when the value of this tag/expression changes. Refresh IDs on startup N/A for OPC .Net Client.