omron — Configuring the Thin Client

Deploying as a Web Application • Viewer.exe • ViewerCfg.exe 3. Copy the files to non-volatile memory on the Windows Embedded device. 4. Register the ISSymbol control on the Windows Embedded device by executing the following command from the Prompt window: regsvrce.exe "\ ISSymbolPath \ISSymbolCE.ocx" Example: 5. Save the registry settings to keep ISSymbolCE.ocx registered when you reboot the Windows Embedded device. regsvrce.exe "\Storage Card\ISSymbolCE.ocx" Tip: Check the device manufacturer's documentation for how to save the registry settings. 6. Start the Secure Viewer by running Viewer.exe .

Changing the Secure Viewer Configuration After initial installation, the configuration of the Secure Viewer is saved in the viewer.ini file, which should be in the same directory as Viewer.exe . (This should be in the \Bin sub-folder where the Secure Viewer program is installed). There are two ways to change the configuration of the Secure Viewer after it has been installed. First, you can run the Viewer configuration utility ( ViewerCfg.exe ) that was also installed. Note: On WIndows Vista and Windows 7, the Secure Viewer configuration utility must have Administrator privileges to run properly.

It should be installed with those privileges by default, but if you still have problems, then check the file properties for ViewerCfg.exe and make sure Run as Administrator is selected. The configuration utility provides the following options: • Save button: Immediately save the current settings to a viewer.ini in the same directory as the ViewerCfg.exe utility. • Import button: Load a viewer.ini file from another directory. • Export button: Save the viewer.ini file to another directory. • Data Server IP field: Enter the IP address (or host name) of your data server station. The data server station is the computer or device where the TCP/IP Server module is running. • TCP Port field:

Enter the port number of the Data Server, if it is different than the default port of 1234. • URL field: Enter the URL or filepath of the project file ( *.app ) on the Web Server. • Enable Splash Window option: Check (enable) this option to see a splash window when you start the Secure Viewer. • Enable Progress Bar option: Check (enable) this option to see a progress bar while the Secure Viewer loads the project file. Page 384 InduSoft Web Studio