omron — StartTask

Appendix: Built-in Scripting Language ShutDown Shuts down all of the active project modules. Syntax ShutDown() This function takes no parameters. Returned value No returned values. Notes This function does not close the development environment , Database Spy , or LogWin . Examples StartTask Starts a project module that is not currently running. Syntax StartTask( strTask ) strTask The name of the task to start (must be one of the following tasks): Returned value No returned values.

Examples InduSoft Web Studio Page 517 Function Group Execution Windows Embedded Thin Client ShutDown Module Activity Asynchronous Supported Supported Not supported Tag Name Expression ShutDown() Function Group Execution Windows Embedded Thin Client StartTask Module Activity Asynchronous Supported Supported Executed on Server Value Description BGTask Background Tasks Viewer Viewer DBSpy Database Spy LogWin LogWin Driver Driver UniDDECl DDE Client UniNDDE DDE Server UniODBC ODBC TCPServer TCP/IP Server TCPClient TCP/IP Client OPCClient OPC Client Tag Name Expression StartTask( "Viewer" )