omron — Preferences tab

Creating a New Project exceptions may not necessarily crash the runtime modules, but they can affect the stability of the system and should be investigated. Note: The Log File is continually appended until it reaches its maximum size of 2MB. After it reaches its maximum size, the existing file is deleted and a new file is created. • Generate a dump file when an unexpected error happens option: When this option is checked, the runtime modules generate a new Dump File ( \Web\Dump\*.dmp ) with useful information about the conditions of the error. This is a binary file that can only be read by the software vendor. Note:

Dump Files are named WinXXX.dmp — where XXX is an identifying number (in hexadecimal format) automatically generated by the system — in order to prevent an existing file from being overwritten when an new error occurs. Therefore, if more than one error occurs, then you will find multiple Dump Files in the directory. The Log File indicates the name of the Dump File associated with each error. • Enable log of memory option: When this option is checked, the runtime modules append the Log File every 15 minutes with information about the current memory allocation.

(The first log entry is written out 15 minutes after the runtime module is started.) This information can be used to identify memory leaks. Even if none of these Quality Feedback options are checked, a post-mortem Dump File ( \Web\Dump \WinDump.dmp ) will always be generated when the runtime module is terminated by a fatal error. However, for debugging purposes, it is strongly recommend that you enable all options in this section and then send the Log File and all Dump Files to your software vendor. Other Preferences • Reset Tags Database when starting project option:

When this option is checked, the project tags are reset automatically whenever you run the project ( Run on the Home tab of the ribbon). See Reset Tags Database for additional details about this feature. • Enforce Web functionality equivalence in local project screens option: When this option is checked, the development software will automatically warn you when you try to select fuctions or features that are incompatible with the remote runtime modules (e.g., Thin Client and Secure Viewer). Note: This option is unchecked by default in order to maintain compatibility with previous versions of InduSoft Web Studio. • Auto reload project on Viewer/Web Clients when it is changed option:

When this option is checked, remote stations (i.e., Thin Clients and Secure Viewers) will check the server to see if they have the most recent version of the project. If they do not, then they will automatically download the new version from the server. InduSoft Web Studio Page 89