Chapter 22 G-Code Editor and E-CAM Editor Cycle 1 Cycle 2 Cycle 3 22.2.3 Using E-CAM Editor Right-click the E-CAM Editor in the project management area and then click New to see a New E-CAM Chart setting window. Type a name and select an item ID and a mode. Users can also set up a password to protect the E-CAM data. After a password is set, the system will ask for the password upon next editing when the mode is set to Graphic Mode . When the mode is set to File mode , the password will be asked for upon each import and export.
22-9 Name Function Description AS AHxxEMC DVPxxMC Item ID E-CAM table item ID Max.16 Max.32 Max.32 ASDA File Using ASDA file format in V File Mode E-CAM table in file mode V Graphic mode E-CAM table in graphic mode V V Flag Cycle When dragging the first and last control point, data synchronization of the two V Password Password for E-CAM table V V Upload E-CAM to File Upload master axis and slave axis position from PLC V