Delta ISPSoft — 3.2.2.6 Search/Find and Replace

Chapter 3 PLC System Configuration & Settings (5) When Find and Replace setting is complete, users can click Replace to replace the module selected with the new module. The search list is updated once Replace is complete and will automatically select the next item. (6) After filling in the setups in the Find and Replace window, users can click Replace All and new modules based on the setting will replace the listed items shown in the window.

* When using AH560 redundant system with Redundancy function enabled, only the main redundant backplane on the left in System Configuration area can perform and replace modules, while the main redundant backplane on the right is configured to mirror the left and cannot be modified. To execute Find and Replace function, the configuration of the main redundant backplane on the right is not on the search list. 3-133