ISPSoft User Manual Single-step execution If the execution of the program stops, single-step execution will be performed after on the toolbar is clicked. Setting the number of times the program is executed If the number of times the program is scanned reaches the number specified, the scan will stop. Besides, the scan of the program is not affected by the breakpoints in the program. Users have to set a number in on the toolbar. The maximum number which can be set is 32767. Click on the toolbar after the setting is complete. Stopping the execution of the program and resetting the execution order After users click on the toolbar, the execution of the program stops.
After on the toolbar is clicked, the execution order and the values will be reset. The execution of the program will start form the beginning of the program next time the program is executed. *. After the debugging mode for a DVP series PLC is enabled, the devices in the device monitoring table still can be monitored. 18-26