B.2 Parameter Table B.2 Parameter Table u A: Initialization Parameters The A parameter group creates the operating environment for the drive. This includes the parameter Access Level, and Password. Parameter can be changed during run. u b: Application Application parameters configure the Run Command Source, DC Injection Braking, and other application-related settings. Parameter List B SIEP C710606 33A OYMC AC Drive – J1000 User Manual 171 No. Name Description Range Def. Mode Addr. Hex Pg. A1: Initialization Parameters Use A1 parameters to configure the basic environment for drive operation. A1-01 Access Level Selection Selects which parameters are accessible via the digital operator. 0:
Operation only 2: Advanced Access Level 0, 2 2 O 101 A1-03 Initialize Parameters Resets all parameters to factory default settings. (Initializes the drive then returns A1-03 to 0) 0: No Initialize 2220: 2-Wire Initialization 3330: 3-Wire Initialization 0 to 3330 0 O 103 70 U2 monitors are not reset when performing initialization. A1-04 Password 1 When the value set into A1-04 does not match the value set into A1-05, parameters A1-01 and A1-03 cannot be changed. 0 to 9999 0 O 104 70 A1-05 Password 2 0 to 9999 0 O 105 70 This parameter is hidden from view. To access A1-05, first display A1-04. Then press the STOP key while holding down the up arrow key. Parameter A1-05 will appear. No.
Name Description Range Def. Mode Addr. Hex Pg. b1: Operation Mode Selection Use b1 parameters to configure the operation mode. b1-01 Frequency Reference Selection Selects the frequency reference input source. 0: Operator - Digital preset speed d1-01 to d1-08 1: Terminals - Analog input terminal A1 2: MEMOBUS/Modbus communications (option) 3: Potentiometer (option) 0 to 3 1 S 180 72 b1-02 Run Command Selection Selects the run command input source. 0: Operator - RUN and STOP keys on the digital operator 1: Digital input terminals 2: MEMOBUS/Modbus communications (option) 0 to 2 1 S 181 73 b1-03 Stopping Method Selection Selects the stopping method when the run command is removed. 0:
Ramp to Stop 1: Coast to Stop 0, 1 0 S 182 74 b1-04 Reverse Operation Selection Permits or prohibits reverse operation. 0: Reverse enabled. 1: Reverse disabled. 0, 1 0 O 183 75 b1-07 LOCAL/REMOTE Run Selection Determines the operation when the Run command source is switched from LOCAL to REMOTE or between REMOTE and MEMOBUS/Modbus communication. 0: External Run command has to be cycled at the new source to be activated. 1: External Run command at new source is accepted immediately. 0, 1 0 O 186 75 b1-08 Run Command Selection while in Programming Mode 0: Run command accepted only in the operation menu. 1: Run command accepted in all menus. 2:
Prohibit entering Programming Mode during Run 0 to 2 0 O 187 75 b1-14 Phase Order Selection Sets the phase order for drive output terminals U/T1, V/T2 and W/ T3. 0 : Standard 1 : Switch phase order 0, 1 0 O 1C3 75 b1-17 Run Command at Power Up Determines the operation when a Run command is active at power up of the drive. 0: Run command not issued, needs to be cycled 1: Run command issued, motor operation start 0, 1 0 O 1C6 76 b2: DC Injection Braking Use b2 parameters to configure DC Injection Braking operation b2-02 DC Injection Braking Current Sets the DC Injection Braking current as a percentage of the drive rated current. 0 to 75 50% O 18A 76