omron — Copy Function (Optional)

4.8 Verifying and Backing Up Parameter Settings 4.8 Verifying and Backing Up Parameter Settings Check changes to parameter settings using the Verify function. Refer to Verifying Parameter Changes: Verify Menu on page 59 . Save the verified parameter settings. Change the access level or set a password to the drive to prevent accidental modification of parameter settings. u Parameter Access Level: A1-01 Setting the Access Level for “Operation only” (A1-01 = 0) allows the user to access parameters A1-  and U  -  only. Other parameters are not displayed. u Password Settings: A1-04, A1-05 The user can set a password to the drive to restrict access.

The password is selected via parameter A1-05. The selected password must be entered in parameter A1-04 to unlock parameter access (i.e., parameter setting A1-04 must match the value programmed into A1-05). The following parameters cannot be viewed or edited until the value programmed into A1-04 correctly matches the value as programmed in parameter A1-05: A1-01 and A1-03. Note: Parameter A1-05 is hidden from view. To display A1-05, access parameter A1-04 and simultaneously depress the key and the key. u Copy Function (Optional) Parameter settings can be copied to another drive to simplify parameter restoration or multiple drive setup. The drive supports the following options:

n USB/Copy Unit The copy unit is an external option connected to the drive to copy parameter settings to another drive. It includes a USB adapter to connect the drive to a PC. n CX-Drive CX-Drive is a PC software tool for parameter management, monitoring, and diagnosis. CX-Drive can load, store, and copy drive parameter settings. For details, refer to Help in the CX-Drive software. 66 SIEP C710606 33A OYMC AC Drive – J1000 User Manual No. Parameter Name Description Setting Range Default A1-01 Access Level Selection Selects which parameters are accessible via the digital operator. 0: Operation only ( A1-01 and A1-04 can be set and monitored. U parameters can be monitored) 2:

Advanced Access Level (All parameters can be set and monitored) 0,2 2