HP — 7-bin Tabletop Mailbox Standalone Diagnostics

7-bin Tabletop Mailbox Standalone Diagnos- tics The standalone diagnostics are designed to test the device’s motors, functionality, and sensors. You will need a power cord, a #2 Phillips screwdriver, and a small flatblade screwdriver for the DIP switches. Note For information on the 3,000-sheet Stapler/Stacker, see HP 3,000- sheet Stapler/Stacker Service Manual Supplement for Paper-Handling Accessories (C4788-90904). Note To change from one test to another or change the DIP switch settings, push the blue power supply switch in (off position), then set to the new test positions. 1 To remove the back cover remove 2 screws (see page 410). 2 Identify the interlock switch.

This black switch is set when the 7-bin Tabletop Mailbox comes into contact with the printer. (Look on opposite side from the paper trays.) This interlock can be defeated by holding it in with a finger or a piece of tape. 3 Identify the DIP switch, SW1 (upper-right corner of the controller PCA). 4 Identify the service LED, LED1 (near the C-link connectors). Table 7-39. DIP switch settings for troubleshooting test C4265-90907 Self-Diagnostics on Paper-handling Devices 689 DIP Switch Normal Settings Motor Test Standalone Running Test Mailbox Stacker Sensor Test 1 Off On On Off Off 2 Off On Off On Off 3 Off Off On Off On 4 Off On Off On On