Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk D3 Series Rotary Solenoid * By using a cooling surface 150 cm 2 , the permissible duty cycle can be extended up to 1.7x normal rating M A = Initial torque M E = End torque (5 ° before end of rotary angle) Coil terminals: - Flying leads - Solder terminal box (A 2.8 x 0.5 DIN 46247) Weight: appr. 150 g Dyn. moment of inertia (rotational mass): appr. 0.35 10 --6 kg m 2 Time constant: appr. 2.5–12 ms All solenoids with M A > 0.6 Ncm are available with spring return, with a rating of M R = 0.5 Ncm approximately. The operational voltage of 205 V DC results from rectifying 230 V AC with a bridge rectifier.
Document RSD300/13 Revision 00 2 Ш4 h9 M3 15 ± 0,5 15 ± 0,5 27,5 3 Ш25 Ш35 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
Voltage ratin g V DC 24 205 V DC V oltage rating ED* LK % 100 38 24 15 4,4 100 39 22 14 5 % ED* LK Current ratin g mA 250 580 870 1.360 4.280 27 67 110 175 407 mA C urrent rating Nominal resi stance 97,2 41,6 27,6 17,6 5,6 7.580 3.065 1.848 1.172 504 Nomin al resistance D 32, 25° MA Ncm 1,15 2,10 2,45 3,50 3,30 4,10 4,25 4,80 6,90 6,30 1,00 2,00 2,10 3,20 3,20 4,00 4,10 4,70 5,90 5,90 Ncm MA D 32, 25° ME Ncm Ncm ME D 33, 35° MA Ncm 0,95 1,85 2,20 3,35 3,00 3,80 3,75 4,30 6,40 4,90 0,80 1,70 2,00 2,80 2,65 3,60 3,60 4,15 5,30 4,80 Ncm MA D 33, 35° ME Ncm Ncm ME D 34, 45° MA Ncm 0,65 1,60 1,80 2,95 2,60 3,40 3,40 3,80 5,60 4,30 0,54 1,40 1,50 2,60 2,30 3,20 3,10 3,80 4,70 4,25 Ncm MA D 34, 45° ME Ncm Ncm ME D 36, 65° MA Ncm 0,43 1,35 1,10 2,40 1,50 2,85 2,20 3,30 4,40 3,70 0,35 1,20 0,88 2,20 1,40 2,70 2,05 3,20 3,50 3,60 Ncm MA D 36, 65° ME Ncm Ncm ME D 39, 95° MA Ncm 0,18 1,20 0,57 2,10 0,90 2,40 1,35 2,50 2,50 2,50 0,14 1,05 0,45 1,95 0,80 2,30 1,20 2,40 2,10 2,50 Ncm MA D 39, 95° ME Ncm Ncm ME
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk D3 Series Ordering Information Order specifications Rotary solenoids Angular travel 25 ° 35 ° 45 ° 65 ° 95 ° Shaft and rotation options Coil terminals Solder terminal box 2) Flying leads (20 cm standard length) Nominal voltage Standard voltage (connected to 230 V AC with Si-bridge rectifier) Perm. duty cycle under air cooled conditions (LK) 2) Suits push-on connector A 2.8 x 1.5 DIN 46247. Insulation class: B (max. permissible temperature = 130 ° C) Test voltage: 2500 V (eff) (D 2:
1500 eff) Document RSD300/23 Revision 00 2 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. D 3 3 -ROR- - F - 24 V DC 100 % ED D 3 2 3 4 6 9 -ROR- F M 24 205 100 % ED
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk D3 Series Shaft & Rotation Options Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Normal Spring return LOO LOL LOR ROO ROL ROR BOO BOL BOR Spring return ØD LF Shaft designs The following types of rotary sole- noids are available. Resulting in the following abbrevia- tions for ordering: 1.
letter Direction of rotation (facing the out put shaft) L anti-clockwise rotation R clockwise rotation B shaft extensions both ends 2. letter Centering shoulder O standard type without mounting ring R optional L optional 3.
letter Return spring – the torque exerted by the spring is to be subtracted from the torque values given in the data sheets L on the anti-clockwise shaft end R on the clockwise shaft end O no return spring fitted B both sides Example 1 anti-clockwise rotation, no return spring, standard shaft length LOO - Example 2 shaft extensions on both ends, return spring on anti-clockwise rotation en BOL - Spring return arrangement (with protection cap) - d 002 Revision RSD300/33 nt Spring return ØD LF Solenoid size 0 Mounting ring Dimensions in mm D3 h1 D M ounting ring Ø D 15,0 Ø LF 6,0 Ø Dh10 13,0 LZ LZ 1,8 e um c Impuls e Automation L imited Do Normal Spring return LOO LOL LOR ROO ROL ROR BOO BOL BOR