EPSON — Setting after Replacing the Substrate (Eye Mark for Reverse Feeding: Use)

L-6534VW Operation Guide Basic Operations Setting after Replacing the Substrate (Eye Mark for Reverse Feeding: Use) This section describes the procedure for setting the Change Substrate screen when you select Use for Eye Mark for Reverse Feeding in Preset for Reverse Feeding. A Set Rewinding Direction on the touch panel. c Important: Set Rewinding Direction correctly. If this is not set correctly, the substrate may become loose and a tension error may occur. B Press Continue . C Select the substrate color. See the following table to select the color of the base color of the substrate or the liner color for clear film. 121