4. Motion Control Instructions 4.6.29. MOV Explanation of the instruction: When EN is On, the content of S will be moved to D without changing the original value in S. MOV is used for sending the 16-bit integer to the target register. Explanation of input and output parameter of the instruction: Note: This instruction is used for moving the 16-bit integer only. Program example When M0 turns Off -> On and keeps in ON status, this instruction will be being executed ever after for sending the content of register D0 to register D100. When M0 turns On→Off, this instruction will stop execution.
DVP-MC operating manual 4-133 API Move 16-bit integer Controller MOV 156 10MC11T Parameter Data Available Explanation name type device EN “MOV” is executed as “EN” turns on. BOOL M,I,Q, constant S The source where the data comes from. INT Constant D The target register INT D