Delta — 4.6.39. ZCP_DI

4. Motion Control Instruction 4.6.39. ZCP_DI Explanation of the instruction: When EN is on, S value is within the range from Low value to High value, Q=On and nQ=Off; if S value is out of the range from Low value to High value, nQ =On, Q=Off; ZCP_DI is used for comparison of the signed 32-bit integer with one zone. When EN is Off, the status of Q and nQ keeps unchanged. Explanation of input and output parameter of the instruction: 4-142 DVP-MC operating manual API Compare 32-bit integer to the values in one zone Controller ZCP DI 166 _ 10MC11T Parameter Data Available Explanation name type device EN “ZCP DI” is executed as “EN” turns on.

_ BOOL M,I,Q, constant S The compared value DINT Constant,D Low The lower limit for zone comparison DINT Constant,D High The high limit for zone comparison DINT Constant,D Q As the instruction is executed and Low ≤S ≤High, the “Q” bit is on. BOOL M,Q nQ As the instruction is executed and High<S or S<Low, the “nQ” bit is on. BOOL M,Q