3. System Installation Electrical specification for the output point #1 : UP and ZP must connect the auxiliary power 24VDC (-15%~20%). 3-2 DVP-MC operating manual Item Content Input channel 4 transistors for output (Source) number Channel type High-speed digital output type for the 4 channels Output terminals Terminal: Q0, Q1, Q2, Q3 Power voltage for 24 VDC(-15% ~ +20%)#1 output point Output delay 2µS ( Off -> On), 3µS ( On -> Off ) Max switch 1KHZ frequency Resistance: 0.5A/1point (2A/ZP) Max loading Inductance: 15W(30VDC) Bulb: 2.5W(30VDC) The Shielded cable: 500m Max cable length The cable without a shield wire: 300m