4. Motion Control Instructions DVP-MC operating manual 4-11 Direction: 0 (Shortest) Direction: 0 (Shortest) Current position: 315° Current position: 315° Target position: 90° Target position: 270° Movement angle: 135° Movement angle: 45° Direction: 2 (Extend current direction) Direction: 2(Extend current direction) Rotary axis status: in state of negative rotation Rotary axis status: be motionless, in state of positive before function block is executed. rotation before function block is executed. Current position: 315° Current position: 315° Target position: 90° Target position: 90° Movement angle: 225° Movement angle: 135°