lexus — 2000 MY for Shift Solenoid ”A” Performance (Shift Solenoid Valve S1) Monitor (P0750)

– Component T/M Outputs Solenoid Cm–37 1996–2003 ADDITION OF OBD (OTH021U) 602 Author : Date:

1MZ–FE (RX300), 2ZZ–GE Following conditions met Rationality check (A) or (Rationality check (B) and Rationality check (C) and Rationality check (D)) It is necessary 2 judgements/driving cycle 1st judgment; temporary flag ON 2nd judgment; pending fault code ON Rationality check (A) Input speed/Output speed (NT/NC) 1.49  NT/NC  1.63 Rationality check (B) Input speed/Output speed (NT/NC) 2.72  NT/NC  2.86 Rationality check (C) Input speed/Output speed (NT/NC) 0.93  NT/NC  1.07 Rationality check (D) Engine speed – Input shaft speed (NE – NT) 250 rpm or more 1ZZ–FE (CELICA), 1NZ–FE [OFF malfunction] Following conditions met OFF malfunction (A) and OFF malfunction (B) It is necessary 2 judgments/driving cycle 1st judgement; temporary flag ON 2nd judgement; pending fault code ON OFF malfunction (A) Input speed/Output speed (NT/NO) 0.64  NT/NO  0.78 OFF malfunction (B) Input speed/Output speed (NT/NO) Changed as follows 0.95  NT/NO [ON malfunction] Following conditions met ON malfunction (A) and ON malfunction (B) and ON malfunction (C) ON malfunction (A) Input speed/Output speed (NT/NO) Not changed as follows 0.95  NT/NO ON malfunction (B) NElast – NEcurrent 1,100 rpm or more ON malfunction (C) Engine speed 3,200 rpm or more 1ZZ–FE (COROLLA) It is necessary 2 judgments/driving cycle 1st judgement; temporary flag ON 2nd judgement; pending fault code ON OFF malfunction Engine speed ON malfunction Engine speed  1.8 x NO + 1,200 rpm