Victron Energy Lithium NG 12,8V — 4.3.2. How to charge batteries before use

Lithium NG 12,8V battery manual 2 3 1. Connect to the BMS using the VictronConnect app. 2. Click on the cog wheel icon at the top right to go to the Settings page. 3. On the Settings page, click on the Option symbol to go to the Product info page. 4. Check to see if you are running the latest firmware. Look for the text “This is the latest version.” 5. To view the battery's current firmware version, return to the Settings page and click the Battery tab. If more than one battery is installed, select the battery by clicking on the battery number (red circle). 4 5 6. If the BMS does not have the most up-to-date firmware, perform a firmware update. Please refer to the BMS manual for details.

4.3. Initial charging before use 4.3.1. Why charge batteries before use This section only applies if you intend to connect batteries in series. Lithium batteries are only approximately 50 % charged when shipped from the factory. This is a transportation safety requirement. However, due to differences in transportation routes and warehousing, the batteries do not always have the same state of charge by the time they are installed. Individually charging new batteries before connecting them in series will shorten the charging time. The built-in battery cell balancing system can only correct small differences in state of charge from one battery to another.

New batteries can have large state of charge differences between them that won't be corrected if installed that way, especially when connected in series. Please note that differences in state of charge between batteries is not the same thing as imbalances between cell voltages within a battery. This is because the cell balancing circuits in one battery cannot affect the cells in another battery. 4.3.2. How to charge batteries before use Always use a BMS-controlled charger when individually charging lithium batteries. Initial charge procedure: 1. If a battery bank consists of batteries connected in series to make a higher voltage bank, each battery must first be charged individually.

Use a dedicated charger or an inverter/charger with a BMS to perform the initial charge. Only a single battery or a bank of parallel connected batteries can be charged as one. Refer to the BMS manual for instructions on how to set it up. 2. Set the charger to the charge profile as indicated in the Charging the battery and recommended charger settings [18] section. 3. Ensure that the battery, the BMS and the charger are communicating with each other. Check this by disconnecting one of the battery BMS cables from the BMS and verifying that the charger turns off. Then reconnect the BMS cable and verify that the charger turns back on. 4.

Turn the charger on and check that the charger is charging the battery. Note that if, during charging, there is any imbalance between the battery cells, then the BMS may turn the charger off and on repeatedly. You may notice that the charger is turned off for a few minutes and then on again for a short period of time before being turned off again. Don't be alarmed; this pattern will repeat itself until the cells are balanced. If the cells are balanced, then the charger will not turn off until the battery is fully charged. Page 11 Installation