© Siemens AG 2010 SIRIUS 3RW Soft Starters 3RW44 Soft Starters for High-Feature Applications 3RW44 SIRIUS 3RW44 for heavy starting (CLASS 20) in inside-delta circuit 4 Order No. supplement for connection types With screw terminals With spring-type terminals 1) In the selection table, the unit rated current I e refers to the induction motor's rated operational current in the inside-delta circuit. The actual current of the device is approx. 58 % of this value. 2) 3RW44 2 soft starters. ... 3RW44 4. with screw terminals: delivery time class } (preferred type). 3) Control by way of the internal 24 V DC supply and direct control by means of PLC possible. Note:
Soft starter selection depends on the rated motor current. peratures > 40 °C and switching frequency, see "Technical spec- ifications". Please observe the notes for the selection of soft starters on Page 4/7. The 3RW44 solid-state soft starters are designed for normal starting (Class 10). (Inertia load of the overall operating mecha- nism J Load Motor ; starting current 350 % x I e for 20 s or similar load). For any other conditions of use, the devices should be selected using the Win-Soft Starter selection and simulation program. For information about rated currents for ambient tem- * You can order this quantity or a multiple thereof.
4/36 Siemens LV 1 · 2010 3RW44 27-1BC44 3RW44 36-6BC44 3RW44 47-6BC44 3RW44 58-6BC44 3RW44 66-6BC44 Ambient temperature 40 °C Ambient temperature 50 °C DT Heavy starting (CLASS 20) in inside-delta circuit PU (UNIT, SET, M) PS* PG Weight per PU approx. Rated opera- tional current Ie1) Rated power of induction motors for rated operational voltage Ue Rated opera- tional current Ie Rated power of induction motors for rated operational voltage Ue 230 V 400 V 500 V 690 V 1000 V A kW kW kW kW kW 200 V 230 V 460 V 575 V A hp hp hp hp Order No. Price per PU Inside-delta circuit, rated operational voltage 200 ...
460 V2) 3RW44 23-@BC@4 3RW44 24-@BC@4 3RW44 25-@BC@4 3RW44 25-@BC@4 3RW44 27-@BC@4 1 3 161 45 90 -- -- -- 196 55 110 -- -- -- 232 75 132 -- -- -- 142 40 50 100 -- B 173 50 60 125 -- B 203 60 75 150 -- B 3RW44 34-@BC@4 1 1 unit 131 7.900 1 1 unit 131 7.900 1 1 unit 131 7.900 3RW44 35-@BC@4 3RW44 36- @ BC @ 4 281 90 160 -- -- -- 352 110 200 -- -- -- 433 132 250 -- -- -- 542 160 315 -- -- -- 617 200 355 -- -- -- 251 75 100 200 -- B 312 100 125 250 -- B 372 125 150 300 -- B 485 150 200 400 -- B 546 150 200 450 -- B 3RW44 43- @ BC @ 4 1 1 unit 131 11.500 1 1 unit 131 11.500 1 1 unit 131 11.500 1 1 unit 131 11.500 1 1 unit 131 11.500 3RW44 44-@BC @ 4 3RW44 45-@BC @ 4 3RW44 47-@BC @ 4 3RW44 47-@BC@4 748 250 400 -- -- -- 954 315 560 -- -- -- 1065 355 630 -- -- -- 1200 400 710 -- -- -- 667 200 250 600 -- C 856 300 350 750 -- C 954 350 400 850 -- C 1065 350 450 950 -- C 3RW44 53-@BC@4 1 1 unit 131 50.000 1 1 unit 131 50.000 1 1 unit 131 50.000 1 1 unit 131 50.000 3RW44 53-@BC@4 3RW44 55-@BC@4 3RW44 57-@BC@4 1351 450 800 -- -- -- 1200 450 500 1050 -- C 3RW44 65-@BC@4 1 1 unit 131 78.000 1524 500 900 -- -- -- 1351 450 600 1200 -- C 3RW44 65-@BC@4 1 1 unit 131 78.000 1680 560 1000 -- -- -- 1472 550 650 1300 -- C 3RW44 65-@BC@4 1 1 unit 131 78.000 -- -- -- -- -- -- 1680 650 750 1500 -- C 3RW44 66-@BC@4 1 1 unit 131 78.000 Order No.
supplement for connection types • With spring-type terminals 2 • With screw terminals 6 Order No. supplement for the rated control supply voltage Us3) • 115 V AC 3 • 230 V AC 4 3RW44 65-@BC@4 3RW44 65-@BC@4 3RW44 65-@BC@4 3RW44 66-@BC@4