© Siemens AG 2010 Solid-State Switching Devices for Resistive Loads Solid-State Contactors SIRIUS 3RF23 solid-state contactors, single-phase 4 Other rated control supply voltages on request. 1) The type current provides information about the performance of the solid- state contactor. The actual permitted rated operational current I e can be smaller depending on the connection method and start-up conditions. For derating see the manual, "Characteristic curves". 2) Utilization category AC-15: Electromagnetic loads, e. g. valves according to EN 60947-5. Parameters: max. 1200 1/h, 50 % ON Period, 10-times inrush current for 60 ms. * You can order this quantity or a multiple thereof.
4/56 Siemens LV 1 · 2010 Type Opera- Rated control supply DT current1) tional voltage Us Imax c Ieu /Arr Cen -1t 52) A A V Screw terminals PU PS* PG Weight (UNIT, per PU SET, M) approx. kg Weight per PU approx. Order No. Price per PU Instantaneous switching Rated operational voltage U 24 ... 230 V e 3RF23 10-1BA02 1 1 unit 101 0.165 3RF23 20-1BA02 1 1 unit 101 0.240 3RF23 30-1BA02 1 1 unit 101 0.400 3RF23 40-1BA02 1 1 unit 101 0.550 3RF23 50-1BA02 1 1 unit 101 0.550 3RF23 70-1BA02 1 1 unit 101 1.200 3RF23 90-1BA02 1 1 unit 101 2.900 10.5 6 24 DC A 20 12 acc. to EN 61131-2 A 30 15 B 40 20 B 50 25 B 50 27.5 B 50 30 B 10.5 6 110 ...
230 AC B 20 12 B 30 15 B 40 20 B 3RF23 10-1 50 25 B 50 27.5 B 50 30 B 3RF23 10-1BA02 3RF23 20-1BA02 3RF23 30-1BA02 3RF23 40-1BA02 3RF23 50-1BA02 3RF23 70-1BA02 3RF23 90-1BA02 3RF23 10-1BA22 1 1 unit 101 0.165 1 1 unit 101 0.240 1 1 unit 101 0.400 1 1 unit 101 0.550 1 1 unit 101 0.550 1 1 unit 101 1.200 1 1 unit 101 2.900 3RF23 20-1BA22 3RF23 30-1BA22 3RF23 40-1BA22 3RF23 50-1BA22 3RF23 70-1BA22 3RF23 90-1BA22 Instantaneous switching Rated operational voltage U 48 ...
460 V e 3RF23 10-1BA04 1 1 unit 101 0.165 3RF23 20-1BA04 1 1 unit 101 0.240 3RF23 30-1BA04 1 1 unit 101 0.400 3RF23 40-1BA04 1 1 unit 101 0.550 3RF23 50-1BA04 1 1 unit 101 0.550 3RF23 70-1BA04 1 1 unit 101 1.200 3RF23 90-1BA04 1 1 unit 101 2.900 10.5 6 24 DC A 20 12 acc. to EN 61131-2 A 30 15 A 40 20 B 50 25 B 50 27.5 B 50 30 B 10.5 6 110 ... 230 AC B 20 12 B 30 15 B 40 20 B 50 25 B 3RF23 20-1 50 27.5 B 50 30 B 20 12 4 ...
30 DC B 30 15 B 50 25 B 3RF23 10-1BA04 3RF23 20-1BA04 3RF23 30-1BA04 3RF23 40-1BA04 3RF23 50-1BA04 3RF23 70-1BA04 3RF23 90-1BA04 3RF23 10-1BA24 1 1 unit 101 0.165 1 1 unit 101 0.240 1 1 unit 101 0.400 1 1 unit 101 0.550 1 1 unit 101 0.550 1 1 unit 101 1.200 1 1 unit 101 2.900 3RF23 20-1BA24 3RF23 30-1BA24 3RF23 40-1BA24 3RF23 50-1BA24 3RF23 70-1BA24 3RF23 90-1BA24 3RF23 20-1BA44 1 1 unit 101 0.240 1 1 unit 101 0.400 1 1 unit 101 0.550 3RF23 30-1BA44 3RF23 50-1BA44 Instantaneous switching · Blocking voltage 1600 V Rated operational voltage U 48 ...
600 V e 3RF23 10-1BA06 1 1 unit 101 0.165 3RF23 20-1BA06 1 1 unit 101 0.240 3RF23 30-1BA06 1 1 unit 101 0.400 3RF23 40-1BA06 1 1 unit 101 0.550 3RF23 50-1BA06 1 1 unit 101 0.550 3RF23 70-1BA06 1 1 unit 101 1.200 3RF23 90-1BA06 1 1 unit 101 2.900 10.5 6 24 DC B 20 12 acc. to EN 61131-2 A 30 15 B 40 20 B 50 25 B 50 27.5 B 50 30 B 10.5 6 110 ...
230 AC B 20 12 B 30 15 B 40 20 B 3RF23 40-1 50 25 B 50 27.5 B 50 30 B 3RF23 10-1BA06 3RF23 20-1BA06 3RF23 30-1BA06 3RF23 40-1BA06 3RF23 50-1BA06 3RF23 70-1BA06 3RF23 90-1BA06 3RF23 10-1BA26 1 1 unit 101 0.165 1 1 unit 101 0.240 1 1 unit 101 0.400 1 1 unit 101 0.550 1 1 unit 101 0.550 1 1 unit 101 1.200 1 1 unit 101 2.900 3RF23 20-1BA26 3RF23 30-1BA26 3RF23 40-1BA26 3RF23 50-1BA26 3RF23 70-1BA26 3RF23 90-1BA26 Type current1) Imax Opera- tional current Ie/AC-152) Rated control supply voltage Us