Siemens — Siemens SIRIUS 3RW Soft Starters and Solid-State Switching Devices Manual

© Siemens AG 2010 Solid-State Switching Devices for Resistive Loads Solid-State Contactors SIRIUS 3RF23 solid-state contactors, single-phase 4 Other rated control supply voltages on request. 1) The type current provides information about the performance of the solid- state contactor. The actual permitted rated operational current I e can be smaller depending on the connection method and start-up conditions. For derating see the manual, "Characteristic curves". 4/59 Siemens LV 1 · 2010 * You can order this quantity or a multiple thereof. Type current1) Rated control supply DT Imax voltage Us A V Ring terminal lug connection PU PS* PG Weight (UNIT, per PU SET, M) approx.

kg Weight per PU approx. Order No. Price per PU Zero-point switching Rated operational voltage U 24 ... 230 V e 3RF23 10-3AA02 1 1 unit 101 0.166 3RF23 20-3AA02 1 1 unit 101 0.200 3RF23 30-3AA02 1 1 unit 101 0.435 3RF23 40-3AA02 1 1 unit 101 0.550 3RF23 50-3AA02 1 1 unit 101 0.550 3RF23 70-3AA02 1 1 unit 101 1.200 3RF23 90-3AA02 1 1 unit 101 2.900 10.5 24 DC B 20 acc. to EN 61131-2 B 30 B 40 B 50 B 70 A 88 B 10.5 110 ...

230 AC B 20 B 30 B 40 B 50 B 3RF23 30-3 70 B 88 B 3RF23 10-3AA02 3RF23 20-3AA02 3RF23 30-3AA02 3RF23 40-3AA02 3RF23 50-3AA02 3RF23 70-3AA02 3RF23 90-3AA02 3RF23 10-3AA22 1 1 unit 101 0.166 1 1 unit 101 0.200 1 1 unit 101 0.435 1 1 unit 101 0.550 1 1 unit 101 0.550 1 1 unit 101 1.200 1 1 unit 101 2.900 3RF23 20-3AA22 3RF23 30-3AA22 3RF23 40-3AA22 3RF23 50-3AA22 3RF23 70-3AA22 3RF23 90-3AA22 Zero-point switching Rated operational voltage U 48 ...

460 V e 3RF23 10-3AA04 1 1 unit 101 0.166 3RF23 20-3AA04 1 1 unit 101 0.200 3RF23 30-3AA04 1 1 unit 101 0.435 3RF23 40-3AA04 1 1 unit 101 0.550 3RF23 50-3AA04 1 1 unit 101 0.550 3RF23 70-3AA04 1 1 unit 101 1.200 3RF23 90-3AA04 1 1 unit 101 2.900 10.5 24 DC B 20 acc. to EN 61131-2 B 30 A 40 B 50 B 70 A 88 A 10.5 110 ... 230 AC B 20 B 30 B 40 B 50 B 70 B 88 B 20 4 ...

30 DC B 30 B 50 B 3RF23 10-3AA04 3RF23 20-3AA04 3RF23 30-3AA04 3RF23 40-3AA04 3RF23 50-3AA04 3RF23 70-3AA04 3RF23 90-3AA04 3RF23 10-3AA24 1 1 unit 101 0.166 1 1 unit 101 0.200 1 1 unit 101 0.435 1 1 unit 101 0.550 1 1 unit 101 0.550 1 1 unit 101 1.200 1 1 unit 101 2.900 3RF23 20-3AA24 3RF23 30-3AA24 3RF23 40-3AA24 3RF23 50-3AA24 3RF23 70-3AA24 3RF23 90-3AA24 3RF23 20-3AA44 1 1 unit 101 0.200 1 1 unit 101 0.435 1 1 unit 101 0.550 3RF23 30-3AA44 3RF23 50-3AA44 Zero-point switching Rated operational voltage U 48 ... 600 V e 3RF23 40-3AA45 1 1 unit 101 0.550 3RF23 70-3AA45 1 1 unit 101 1.200 3RF23 90-3AA45 1 1 unit 101 2.900 40 4 ...

30 DC B 70 A 88 B 3RF23 40-3AA45 3RF23 70-3AA45 3RF23 90-3AA45 Zero-point switching · Blocking voltage 1600 V, rated operational voltage U 48 ... 600 V e 3RF23 10-3AA06 1 1 unit 101 0.166 3RF23 20-3AA06 1 1 unit 101 0.200 3RF23 30-3AA06 1 1 unit 101 0.435 3RF23 40-3AA06 1 1 unit 101 0.550 3RF23 50-3AA06 1 1 unit 101 0.550 3RF23 70-3AA06 1 1 unit 101 1.200 3RF23 90-3AA06 1 1 unit 101 2.900 10.5 24 DC B 20 acc. to EN 61131-2 B 30 B 40 B 50 B 70 B 88 B 10.5 110 ...

230 AC B 20 B 30 B 40 B 50 B 70 A 88 B 3RF23 10-3AA06 3RF23 20-3AA06 3RF23 30-3AA06 3RF23 40-3AA06 3RF23 50-3AA06 3RF23 70-3AA06 3RF23 90-3AA06 3RF23 10-3AA26 1 1 unit 101 0.166 1 1 unit 101 0.200 1 1 unit 101 0.435 1 1 unit 101 0.550 1 1 unit 101 0.550 1 1 unit 101 1.200 1 1 unit 101 2.900 3RF23 20-3AA26 3RF23 30-3AA26 3RF23 40-3AA26 3RF23 50-3AA26 3RF23 70-3AA26 3RF23 90-3AA26 Type current1) Imax Rated control supply voltage Us