© Siemens AG 2010 Solid-State Switching Devices for Switching Motors Solid-State Contactors SIRIUS 3RF24 solid-state contactors, three-phase Overview These two-phase controlled, instantaneous switching solid-state contactors in the insulting enclosure are offered in 45 mm width to 5.2 A – and in 90 mm width to 16 A. This means that it is pos- sible to operate motors up to 7.5 kW. The devices with screw connection can use a link module 1) to di- rectly connect to a circuit breaker. Direct mounting on a 3RB20 electronic overload relay 2) is possible. Rapid-switching fuseless and fuse motor feeders can thereby be implemented in a time- saving manner.
Selection and ordering data Motor contactors · Instantaneous switching · Two-phase controlled 4 1) For 3RA19 21-1AA00 link modules see next page. 2) For 3RB20 overload relays see Chapter 5. * You can order this quantity or a multiple thereof. 4/76 Siemens LV 1 · 2010 Rated opera- Rated power at Rated control supply DT tional current IeIe and Ue voltage Us 400 V A kW V Screw terminals PU PS* PG Weight (UNIT, per PU SET, M) approx. kg Weight per PU approx. Order No. Price per PU Rated operational voltage U 48 ... 460 V e 3RF24 05-1BB04 1 1 unit 101 0.250 3RF24 10-1BB04 1 1 unit 101 0.380 3RF24 12-1BB04 1 1 unit 101 0.380 3RF24 16-1BB04 1 1 unit 101 0.380 5.2 2.2 24 DC A 9.2 4.0 acc.
to EN 61131-2 B 12.5 5.5 B 16 7.5 B 5.2 2.2 110 ... 230 AC B 9.2 4.0 B 12.5 5.5 B 16 7.5 B 3RF24 05-1BB 3RF24 05-1BB04 3RF24 10-1BB04 3RF24 12-1BB04 3RF24 16-1BB04 3RF24 05-1BB24 1 1 unit 101 0.250 1 1 unit 101 0.380 1 1 unit 101 0.380 1 1 unit 101 0.380 3RF24 10-1BB24 3RF24 12-1BB24 3RF24 16-1BB24 Rated operational voltage U 48 ... 600 V, e blocking voltage 1600 V 3RF24 05-1BB06 1 1 unit 101 0.250 3RF24 10-1BB06 1 1 unit 101 0.380 3RF24 12-1BB06 1 1 unit 101 0.380 3RF24 16-1BB06 1 1 unit 101 0.380 5.2 2.2 24 DC B 9.2 4.0 acc. to EN 61131-2 B 12.5 5.5 B 16 7.5 B 5.2 2.2 110 ...
230 AC B 9.2 4.0 B 12.5 5.5 B 16 7.5 B 3RF24 10-1BB 3RF24 05-1BB06 3RF24 10-1BB06 3RF24 12-1BB06 3RF24 16-1BB06 3RF24 05-1BB26 1 1 unit 101 0.250 1 1 unit 101 0.380 1 1 unit 101 0.380 1 1 unit 101 0.380 3RF24 10-1BB26 3RF24 12-1BB26 3RF24 16-1BB26 Rated opera- tional current Ie Rated power at Ie and Ue Rated control supply voltage Us Rated opera- Rated power at Rated control supply DT tional current IeIe and Ue voltage Us 400 V A kW V Spring-type terminals PU PS* PG Weight (UNIT, per PU SET, M) approx. kg Weight per PU approx. Order No. Price per PU Rated operational voltage U 48 ...
460 V e 3RF24 05-2BB04 1 1 unit 101 0.250 3RF24 10-2BB04 1 1 unit 101 0.380 3RF24 12-2BB04 1 1 unit 101 0.380 3RF24 16-2BB04 1 1 unit 101 0.380 5.2 2.2 24 DC B 9.2 4.0 acc. to EN 61131-2 B 12.5 5.5 B 16 7.5 B 5.2 2.2 110 ... 230 AC B 9.2 4.0 B 12.5 5.5 B 16 7.5 B 3RF24 10-2BB 3RF24 05-2BB04 3RF24 10-2BB04 3RF24 12-2BB04 3RF24 16-2BB04 3RF24 05-2BB24 1 1 unit 101 0.250 1 1 unit 101 0.380 1 1 unit 101 0.380 1 1 unit 101 0.380 3RF24 10-2BB24 3RF24 12-2BB24 3RF24 16-2BB24 Rated operational voltage U 48 ...
600 V, e blocking voltage 1600 V 3RF24 05-2BB06 1 1 unit 101 0.250 3RF24 10-2BB06 1 1 unit 101 0.380 3RF24 12-2BB06 1 1 unit 101 0.380 3RF24 16-2BB06 1 1 unit 101 0.380 5.2 2.2 24 DC B 9.2 4.0 acc. to EN 61131-2 B 12.5 5.5 B 16 7.5 B 5.2 2.2 110 ... 230 AC B 9.2 4.0 B 12.5 5.5 B 16 7.5 B 3RF24 05-2BB06 3RF24 10-2BB06 3RF24 12-2BB06 3RF24 16-2BB06 3RF24 05-2BB26 1 1 unit 101 0.250 1 1 unit 101 0.380 1 1 unit 101 0.380 1 1 unit 101 0.380 3RF24 10-2BB26 3RF24 12-2BB26 3RF24 16-2BB26 Rated opera- tional current Ie Rated power at Ie and Ue Rated control supply voltage Us