© Siemens AG 2010 BETA Protecting SITOR Semiconductor Fuses SILIZED, NEOZED and DIAZED design Overview Benefits SILIZED is the brand name for NEOZED fuses (D0 fuses) and DIAZED fuses (D fuses) with super quick characteristic for semi- conductor protection. The fuses are used together with fuse bases, fuse screw caps and accessories of the standard fuse system. SILIZED fuses have an extremely compact design. This means they have a very small footprint - particularly the NEOZED version The rugged and well-known DIAZED design complies with IEC 60269-3. It is globally renowned and can be used in many countries.
A huge range of fuse bases and accessories are available for the NEOZED and DIAZED versions of the SILIZED fuses. This increases the application options in many devices. SILIZED fuses protect power semiconductors from the effects of short circuits because the super quick disconnect characteristic is far quicker than that of conventional fuses. They protect ex- pensive devices and system components such as solid-state contactors, static relays, converters with fuses in the input and in the DC link, UPS systems and soft starters for motors up to 100 A.
If using fuse bases and fuse screw caps made of molded plas- tic, always take into account the maximum permissible values of power loss due to the high power dissipation (power loss) of the SILIZED fuses. If using these components, the following maxi- mum permissible power losses apply: NEOZED D02: 5.5 W DIAZED DII: 4.5 W DIAZED DIII: 7.0 W For this reason, sometimes a thermal permanent load of only 50 % is possible. The DIAZED screw adapter DII for 25 A is used for the 30 A fuse link. Selection and ordering data 19 19/111 Siemens LV 1 · 2010 * You can order this quantity or a multiple thereof. Size Ie Ue B I2r te va ak li un eg P loo sw ser DT A V AC/ A2s W V DC Order No.
Price per PU PU PS* PG Weight per PU approx. Unit(s) Unit(s) kg Weight per PU approx. SILIZED fuse links, NEOZED design operational class gR D01 10 400/250 73 6.9 B 16 120 6.2 B D02 20 190 8.1 B 25 215 8.2 B 35 470 16.7 B 50 1960 12.0 B 63 4230 15.5 B 1 10 016 0.006 1 10 016 0.007 1 10 016 0.012 1 10 016 0.012 1 10 016 0.012 1 10 016 0.013 1 10 016 0.014 5SE1 310 5SE1 316 5SE1 320 5SE1 325 5SE1 335 5SE1 350 5SE1 363 Size Ie Ue B I2r te va ak li un eg P loo sw ser DT A V AC/ A2s W V DC Order No. Price per PU PU PS* PG Weight per PU approx. Unit(s) Unit(s) kg Weight per PU approx.
SILIZED fuse links, DIAZED design operational class gR DII 16 500/500 60 12.1 A 20 139 12.3 A 25 205 12.5 A 30 310 13.5 A DIII 35 539 14.8 A 50 1250 18.5 A 63 1890 28 A DIV 80 4200 34.3 B 100 8450 41.5 B 1 5 016 0.028 1 5 016 0.029 1 5 016 0.031 1 5 016 0.031 1 5 016 0.050 1 5 016 0.051 1 5 016 0.054 1 3 016 0.110 1 3 016 0.110 5SD4 20 5SD4 30 5SD4 40 5SD4 80 5SD4 50 5SD4 60 5SD4 70 5SD5 10 5SD5 20