LVS-7500 External System Installation and Quick Start Guide Line 5 (D3) – The Audible Alarm, located inside the Stop Motion/Light Tower Unit, is programmed to follow the RED light (Line 3). When the audible alarm is not required, the operator will have to change the INI settings. There is no access to Line 5 through the Alarm Matrix.
LVS-7500 External System Installation and Quick Start Guide Page 45 of 45 CN5 Stop Motion Relay Output (Active Low) Pin Assignment Wire Color Directions 1 – USB 5VDC Not used 2 – Normally open relay contact RED Active-Low +5VDC Signal 3 – Common relay contact BLACK Jumper to Pin 5 (Ground) 4 – Normally closed relay contact WHITE Not used CN5 Stop Motion Relay Output (Active High) Pin Assignment Wire Color Directions 1 – USB 5VDC Connect a 1K resistor (1/2 watt) from Pin 1 to Pin 4 2 – Normally open relay contact RED Not used 3 – Common relay contact BLACK Jumper to Pin 5 (Ground) CN5 Stop Motion Relay Output (Relay Contacts Only) Pin Assignment Wire Color Directions 1 – USB 5VDC Not used 2 – Normally open relay contact RED 3 – Common relay contact BLACK 4 – Normally closed relay contact WHITE