Lynx Smart BMS 5.4.8. Connect the GX device Connect the Lynx Smart BMS VE.Can port to the GX device VE.Can port using a RJ45 cable. Multiple VE.Can devices can be daisy chained, but make sure that the first and the last VE.Can device both have a VE.Can RJ45 terminator installed. Power the GX device from the AUX + and AUX – terminal of the Lynx Smart BMS. RJ45 VE.Can connectors Location of the VE.Can connectors on the Lynx Smart BMS Wiring example Lynx Smart BMS and a CCGX 5.5. System examples in detail 5.5.1. Lynx Smart BMS, 2x Lynx Distributor and lithium batteries A Lynx Smart BMS with two Lynx distributors and a Cerbo GX with GX touch panel form the heart of this system.
They continuously monitor the batteries, fuses, connected loads, chargers and inverter/charger(s). A typical system can contain the following components: Lynx Smart BMS with built-in contactor and battery monitor. Lynx Distributor with 2 fused paralleled lithium batteries and identical cable lengths for each battery (up to 20 batteries can be used per system - see the Lithium Battery Smart manual for details). Lynx Distributor with fused connections for chargers, inverter/charger(s) and loads. A Cerbo GX (or other GX device). Page 13 Installation VE.Can RJ45 terminator RJ45 UTP cable VE.Can RJ terminator GX device power cables 45