Downloaded from https://www.everyspec.com AMCP 706-134 means of attaching it, and make the means of because of space limitations, place the unit re- attaching it simple as possible. quiring less frequent access in the back or on (19) Keep the weight of components under the bottom. 30 lb if possible. (15) Avoid the situation where frames and (20) Provide adequate handles on all units struettural members interfere with maintenance weighing more than 10 hl, and on those weigh- and operational personnel reaching components ing less than 10 lb if they might otherwise be they must maintain, inspect, or operate (oee difficult to gLasp, remove, or hold (see Para- Figure 23-11). graph 23-6).
(14) Install components that require fre- quent visual inspection in positions where they 23-4 LOCATION OF INDIVIDUAL can be seen easily without removing panels, COMPONENTS covers, o.' other units. Consider the following when locating indi- U THIS NOT TIS NOT THIS vidual components: (1) Locate equipment components to mini- mize the possibility of equipment damage or BACK OF BACK OF personnel injury. UNI UNIT (2) Locate delicate components where they HINGEN will not be damaged while the equipment is HINGE SACK OFNI being worked on. (8) Place component'q in pos.tions where oil, other iluids, and dirt are nut likely to fall on them.
(4) Guard high temperature parts or locate so that personnel contact will not occur during operation or maintenance. Arrange and shield Figure 23-10. Hinged Units heat producing equipment so that discomfort to personnel is avoided. i (5) Enclose high current switching devices THiS to protect personnel. Do not locate internal con- trols close to dangerous voltages. (6) Lay out components so that they are accessible to both operating personnel and me ntenance technicians. (7) Group components maintained by the same technician. They should be laid out so that, during system checking, a minimum of moving from position to position is necessary.
(8) Place check points, adjustment points, cable-end connections, and labels in full view NOT THIS of the technician. (9) Provide that small hinge mounted units, which must have access to the back, are free to open their full distance and remain open with- out being held (see Figure 23-10). (10) Make components and systems requir- ing frequent inspection and maintenance as .. easily accessible as possible. - (11) Locate units so no other equipment h:s to be removed to gain access to them. (12) Do not stack units. If it is necessary Figure 23-1I. Component Placement 23-6 I.I