Victron BMV-700H — 4.5. Make Lithium settings (if needed)

Manual - BMV-700H Battery capacity. Charged voltage. State of charge or start synchronised. If lithium batteries (or batteries with a different chemistry) are used, some additional settings will have to be changed. First, make the essential settings as described in this paragraph and then refer to the next paragraph for the special lithium settings. For more information about these and any of the other settings, see chapter All features and settings [23] . 4.4.1. Set the battery capacity value In the VictronConnect app, see: Settings > Battery . Via the head unit, see: Setup menu > Setting 01 - Battery capacity . The battery monitor is by default set to 200Ah.

Change this value to match your battery capacity. For lead-acid batteries, we recommend entering the 20-hour (C20) rate. 4.4.2. Set charged voltage value Via the head unit, see: Setup menu > Setting 02 - Charged voltage . In the VictronConnect app, see: Settings > Battery > Charged voltage . These are the recommended “Charged voltage” values for lead acid batteries: Use multiples of the 12V charge voltage, i.e. 13.2V, or consult the battery documentation. For more information, also see the Charged voltage [24] chapter. 4.4.3. Set state of charge In the VictronConnect app, see: Settings > Battery > Battery start synchronized . Via the head unit, see:

Setup menu > Setting 70 - Start synchronised . When set to ON, the battery monitor will consider itself synchronized when powered up, resulting in a state of charge of 100%. If set to OFF, the battery monitor will consider itself un-synchronized when powered up, resulting in a state of charge that is unknown until the first actual synchronization. For VictronConnect only: The initial state of charge value can also be manually set, by default, this is 100%, and can be set to a different value if so desired. See: Settings > Battery > State-of-charge . 4.5. Make Lithium settings (if needed) LiFePO4 (Lithium Iron Phosphate or LFP) is the most used Li-ion battery chemistry.

The factory defaults are in general also applicable to LFP batteries with exception of these settings: Tail current. Peukert exponent. Charge efficiency. Discharge floor. Tail current In VictronConnect see: Settings > Battery > Tail current . Via the head unit, see: Setup menu > Setting 03 - Tail current . Some lithium battery chargers stop charging when the current drops below a set threshold. The tail current must be set higher in this case. Peukert exponent In VictronConnect see: Settings > Battery > Peukert exponent . Page 13 Configuration