Manual - BMV-700H Press SELECT again to stop scrolling and show the value. Press SELECT again to leave the historical menu and to go back to the normal operation mode. The below table gives an overview of the history parameters and how they are displayed in the menu. For the meaning of each parameter see the next chapter. 5.5.3. History data Discharge information in Ah Deepest discharge: The battery monitor remembers the deepest discharge and each time the battery is discharged deeper the old value will be overwritten. Last discharge:

The battery monitor keeps track of the discharge during the current cycle and displays the largest value recorded for Ah consumed since the last synchronisation. Average discharge: The cumulative Ah drawn divided by the total number of cycles. Cumulative Ah drawn: The cumulative number of Amp hours drawn from the battery over the lifetime of the battery monitor. Energy in kWh Discharged energy: This is the total amount of energy drawn from the battery in kWh. Charged energy: The total amount of energy absorbed by the battery in kWh. Charge Total charge cycles: The number of charge cycles over the lifetime of the battery monitor.

A charge cycle is counted every time the state of charge drops below 65% and then rises above 90%. Time since last full charge: The number of days since the last full charge. Synchronisations: The number of automatic synchronisations. A synchronisation is counted every time the state of charge drops below 90% before a synchronisation occurs. Page 18 Operation # Display Discription A Deepest discharge B Last discharge C Average discharge D Cycles E Discharges F Cumulative Ah G Lowest voltage H Highest voltage I Days since last full charge J Synchronisations L Low voltage alarms M High voltage alarms R Discharged energy S Charged energy