Victron BMV-712 Smart — 3.7. Programmable relay

Manual - BMV-712 Smart 1. Connect the ferrule pin of the second red cable with fuse to the shunt by pushing the pin into to the +B2 terminal. 2. Connect the M10 lug of the second red cable with fuse to the positive terminal of the midpoint. For more information on midpoint monitoring and for additional diagrams on midpoint battery bank wiring see the Midpoint voltage monitoring [46] chapter. Loads & Chargers Battery monitor with auxiliary midpoint monitoring. 3.6.3. Auxiliary connection for temperature monitoring For use to monitor the temperature of a battery via the (not included) Temperature sensor for BMV-712 Smart and BMV-702 . This temperature sensor needs to be purchased separately.

Be aware that this is a different temperature sensor than the temperature sensors that are included with Victron inverter/chargers and some battery chargers. Temperature sensor for the battery monitor Connection procedure: Connect the ferrule pin of the black temperature sensor wire by pushing the ferule pin into the +B2 terminal. Connect the ferrule pin of the red wire cable by pushing the ferule pin into to the +B1 terminal. Connect the M10 cable lug of the temperature sensor to the positive battery terminal. Battery monitor with auxiliary temperature sensing. Note that if the temperature sensor is used, the two red cables with fuse that came with the battery monitor are not needed.

The temperature sensor will replace these cables. 3.7. Programmable relay The battery monitor is equipped with a programable relay. This relay can be used as an alarm relay, to start a generator or for other applications. For more information on the various relay modes and how to configure the relay, see chapter Relay settings [32] . Page 9 Installation Loads & Chargers