Manual - BMV-712 Smart The battery monitor is connected to a Cerbo GX and a GX Touch screen. 3.10. Wiring for use as DC meter When using the battery monitor as a DC meter, wire it to the device or circuit that needs to be monitored. Note that the battery monitor also needs to be configured as a DC monitor using the VictronConnect app before it will operate as a DC monitor. See the Configure for use as DC meter [17] chapter. It is also possible to have a main battery monitor in the system together with a separate battery monitor that has been set up as a DC meter to monitor a specific device or circuit.
Wiring example of a system containing a main battery monitor, together with a battery monitor that has been set up as a DC meter and is monitoring a specific device or circuit. One battery monitor is used as a DC meter (B) and the other battery monitor is used as a battery monitor (D). Page 11 Installation # Description A Specific DC device or DC circuit B Battery monitor used as DC meter C The rest of the DC circuit D Battery monitor used as battery monitor